Connector current reference

Enter the current you need to carry and see which connectors handle it. Connectors that fall short stay in the list, dimmed, so the spread between them is visible.

Continuous current, not the peak your ESC pulls for a second.

What it is for

Connectors rated for 30 A

6matches

The smallest one that does the job is XT30. Going bigger than you need costs weight and board space, not safety.

  • Caution

    JST-XH is not on this list for power, and should not be

    A balance connector carries the few milliamps a charger moves between cells. People reach for one because it is on the pack already and the crimps look the same. It is a fire path. Its rating is listed as not a power connector for that reason.

  • Caution

    Dupont jumpers are never the answer for power

    The rating you find quoted assumes a perfect crimp you did not get. Treat the real limit as 1 A, use them for prototyping signal, and never put motor or battery current through one.

  • Note

    These are planning numbers

    Vendor ratings vary, and cheap clones underperform the genuine part by a wide margin. A clone XT60 with thin contacts and poor plating does not carry 60 A. Use this table to narrow the choice, then check the datasheet of the part you are actually buying.

The full list

Connectors that do not meet the requirement stay here, dimmed and marked, because the spread between them is the useful thing to know.

ConnectorContinuousBurstWhat it is for
XT30Tight30 A40 ASmall drone packs, 3 to 4 inch builds
XT6060 A180 A shortStandard 5 inch drone and general LiPo packs
XT9090 A120 ALarge packs, high current sleds
MR30Tight30 A40 ACompact alternative to XT30 on micro builds
Deans / T plug60 A100 AOlder RC standard, largely replaced by XT60
Anderson Powerpole 15/30/4515 / 30 / 45 A per contactHigher, short durationBench supplies, field power, hot swap
Molex Micro-Fit 3.08.5 A per circuit-Below the current you need · Board to wire power inside enclosures
Barrel jack 5.5 x 2.1 mm5 A-Below the current you need · Wall adapter input, low current DC
USB-C3 A, 5 A with e-marker-Below the current you need · Charging and 5 V power
JST-RCY (red)3 A-Below the current you need · Small battery packs, low current motors
JST-PH 2.02 A-Below the current you need · Single cell LiPo on dev boards
JST-SM3 A-Below the current you need · LED strips and inline signal or low power
JST-XHNot a power connector-Not a power connector · Cell balance leads only
Dupont jumper1 A practical, 3 A rated-Not intended for power · Prototyping signal, never power
Screw terminal 5.08 mm15 to 20 A-Below the current you need · Fixed installs, solar and mains adjacent DC
  • Anderson Powerpole 15/30/45 · The rating follows the contact you crimp in, not the housing. A 45 A housing with 15 A contacts is a 15 A connector.
  • JST-XH · JST-XH is a balance connector. It carries the few milliamps a balance charger moves between cells. Using it to carry pack current is a fire path.
  • Dupont jumper · Dupont jumpers are a prototyping convenience. The crimp is loose, the contact area is small, and the rating assumes a perfect crimp you did not get. Treat the real limit as 1 A and never use them for motor or battery current.

Why this matters

Connector choice is where a correctly sized wire gets undone. The wire is a solid length of copper; the connector is two pieces of thin plated metal pressed together, and all the current in the system squeezes through that contact patch. A connector rated for signal current melts long before the wire does, and the failure is usually a slow one: the contact heats, the plating oxidises, resistance rises, it heats more. By the time anyone notices, the housing has deformed and the pin is welded in place.

Assumptions and sources

  • Every figure is a planning number, not a specification. Vendor ratings vary and cheap clones underperform the genuine part by a wide margin.
  • Continuous ratings assume a proper crimp or a full solder joint, correctly sized wire, and room temperature air. A cold solder joint or an undersized wire moves the limit down.
  • Burst figures are short duration only, measured in seconds. They are not a rating you design around.
  • Anderson Powerpole ratings follow the contact crimped into the housing, not the housing itself.